Validation of a multiscale Hill-type actuator against comprehensive benchmarks of motor unit and muscle force measurements

Avatar
Poster
Voice is AI-generated
Connected to paperThis paper is a preprint and has not been certified by peer review

Validation of a multiscale Hill-type actuator against comprehensive benchmarks of motor unit and muscle force measurements

Authors

Sgarzi, A.; Caillet, A. H.; Millard, M.; Weidner, S.; Haralabidis, N.; Meranger, T.; Bolsterlee, B.; Farina, D.; Lovell, N. H.; Modenese, L.

Abstract

Computational Hill-type muscle models are widely used to simulate muscle force production because of their efficiency and physiological interpretability. However, their formulation relies on limiting assumptions, including debated multiscale simplifications, a simplified excitation-activation dynamics and an inability to capture slow and fast fibres. Moreover, existing Hill-type models remain insufficiently validated across physiological scales, fibre types, and contraction modes. We addressed these limitations by developing a multiscale fibre-type specific Hill-type neuromuscular actuator with mechanistic excitation-activation dynamics and systematically validated it against comprehensive experimental benchmarks. The model built upon a previously proposed motoneuron-driven actuator incorporating calcium-kinetics-based activation dynamics. The excitation-activation formulation was further refined to strengthen its physiological basis, while the contraction dynamics was extended by including an activation- and length-dependent force-velocity relationship, elastic tendon, passive elastic element, and the fibre-type-specific effects of yielding and sag. Validation was performed against four benchmark datasets spanning motor-unit and whole-muscle scales, including slow and fast fibres under both isometric and dynamic conditions. Experimental force traces were obtained from six muscles of rats and cats using a broad range of stimulation frequencies, muscle lengths, and imposed length changes, combining previous literature datasets with experiments performed ad hoc for this study. Overall, the model reproduced forces across all benchmark conditions, with mean absolute errors typically below 15% of the maximum isometric force, although larger errors were observed in specific submaximal and dynamic trials. The inclusion of physiologically based excitation-activation dynamics, together with yielding and sag, improved model performance under submaximal activation conditions. This study presents the first systematic validation of a single multiscale Hill-type neuromuscular actuator against comprehensive experimental motor unit and muscle force data, providing a benchmark framework for the development and assessment of future models.

Follow Us on

0 comments

Add comment